HMI_Logo HMI Ring Diagrams
Pipeline Script Specifications

avg120

Script Version
	1.1	14 XI 2011

General Description
	Produces averages of the power spectra at each target location over a selected
	Carrington rotation

Status
	Included in JSOC release 6.0
	The script is in the JSOC CVS repository

Usage
	avgpsbycr [-test] size CR
	
Arguments
	-test		If specified, the output series will be in namespace hmi_test;
			otherwise it is in hmi

	size		A code for the ring-diagram synoptic tiel set to be averaged
			Valid values are: 5, 15, and 30 

	CR		The Carrington rotation number of the averaging interval

Input Data Series:
	hmi.rdVpspec_fd05
	hmi.rdVpspec_fd15
	hmi.rdVpspec_fd30

Output Data Series:
	hmi[_test].rdVavgpspec_fd05
	hmi[_test].rdVavgpspec_fd15
	hmi[_test].rdVavgpspec_fd30

Modules invoked:
	datavg

Auxiliary Files used:
	~rick/rings/notify (for addresses of email notifications)

Fixed Parameter Values:
	datavg: mean= logP mscale= 0.0005 mzero= -11.5

Sample commands:
	avgpsbycr 15 2100
	avgpsbycr -test 30 2100 360

Changes from Previous Version
	— uses current version of datavg, rather than datavg_v10

Bugs in current version
	There is no provision in the test mode for using a specified module version


Valid HTML 4.01 Transitional HMI Ring Diagrams 15 Nov 2011, 16:40-0800